• Sumset International Trading Co.,Ltd
    Bruno Nascimento
    Thank you for your continued help and support in providing us with high-quality and affordable products.
  • Sumset International Trading Co.,Ltd
    Ehsan Salmari
    Prompt reply and professional attitude make our cooperation smoother!
Contact Person : kerry
Phone Number : 18150137563
Whatsapp : +8618150137563

IOC10 Mk2 I/O Communication Interface Module | VM600 Mk2 System Partner for Temperature & Analog Monitoring

Place of Origin Switzerland
Brand Name Proximity Sensor
Certification COO ,COC ,CQ
Model Number IOC10 Mk2
Document IOC10 Mk2.pdf
Minimum Order Quantity 1
Price $11999
Delivery Time 5-7days
Payment Terms T/T
Supply Ability 999
Product Details
Brand Proximity Sensor Model Number IOC10 Mk2
Function Good Condition New
Warranty 1 Year
Highlight

IOC10 Mk2 I/O Module

,

VM600 Mk2 Interface Module

,

Temperature Analog Monitoring Module

Leave a Message
Product Description
Product Overview

The IOC10 Mk2 is the matching input-output and communication interface card built for the VM600 Mk2 rack. It works paired with the AMC10 Mk2 module, handling signal transfer, data transmission, and internal bus communication for all 10 channels of analog and temperature measurements. It cannot run alone; it acts as the data bridge to send collected sensor readings to the rack controller and host system.

Key Features & Benefits
  • Dedicated match for the AMC10 Mk2, ensuring stable data transmission for 10-channel RTD, thermocouple, and analog signals.
  • Fast internal rack bus communication keeps measurement data updated in real time without noticeable delay.
  • Built-in circuit diagnosis continuously checks the link status between itself and the paired AMC10 Mk2.
  • Simple rack slot installation — plug-and-fit for existing VM600 Mk2 setups, with no extra wiring cabinets required.
  • Supports standard system log output, helping engineers trace alarm records and signal faults quickly.
Application Value

The IOC10 Mk2 completes the temperature and analog monitoring loop together with the AMC10 Mk2 for critical rotating machinery. It reliably delivers bearing temperature, lube oil temperature, and auxiliary pressure data to your DCS or monitoring host. It keeps your machine condition data synchronized with vibration protection data, so operators get a complete picture of machine health. This stable link lowers the risk of missing temperature alarms on turbines, compressors, and pumps at power, oil & gas, and petrochemical sites.

Technical Specifications
Model Number Part Number / Details
IOC10 Mk2 PNR 600-061
AMC10 Mk2 PNR 600-059
MPC4 200-510-071-113
EC119 922-119-000-003-P2000-U2000
EC119 922-119-000-003-P5000-U5000
CE311 444-311-00-023
CA202 144-202-000-205
TQ402 111-402-000-013 A1-B1-C045-D000-E010-F0-G000-H10
TQ402 111-402-000-013 A1-B1-C045-D000-E050-F0-G000-H05
TQ902 111-902-000-011 A1-B1-C70-D2-E1000-F0-G0-H10
IPC704 244-704-000-042 A1-B03-C100-D100-E5-F2000-G0-H0-I0
EA402 913-402-000-013 A1-E090-F0-G000
IQS450 204-450-000-002 A1-B21-H10-I0
Product Images
IOC10 Mk2 I/O Communication Interface Module | VM600 Mk2 System Partner for Temperature & Analog Monitoring
IOC10 Mk2 I/O Communication Interface Module | VM600 Mk2 System Partner for Temperature & Analog Monitoring
Engineering Recommendations
  • Always pair the IOC10 Mk2 strictly with the AMC10 Mk2; mixing it with other module types will cause communication failure.
  • Check firmware version consistency between paired cards before power-on.
  • Avoid placing this card next to high-power relay modules to reduce electrical noise interference.
  • Carry out link testing after rack wiring is finished.
Global Applications
Asia Pacific

China, South Korea, Japan, India, Southeast Asia

Middle East

Saudi Arabia, UAE, Qatar

North America

United States, Canada

Europe

Germany, United Kingdom, France, Russia, Turkey

Latin America

Brazil, Argentina, Mexico

Typical Applications
  • Rotating machinery online protection systems
  • Vibration and shaft-position monitoring
  • Steam turbine and compressor safety supervision
  • Large fan, generator, and high-speed pump condition monitoring
  • Oil and gas facilities
  • Chemical processing plants
  • Power generation facilities
  • Metal processing and coal-chemical plants
Our Advantages
  • Export to 40+ countries
  • Complete after-sales service
  • Stable supply chain ensuring continuous availability
  • COO, COC, and CQ certification support
  • Rapid quotation response
Installation Reference
AMC10 Mk2 module installation mounting reference diagram showing rack slot placement
IOC10 Mk2 installation reference diagram illustrating wiring and module positioning
Installation Requirements
  • Professional installation is required for optimal performance and safety.
  • Ensure proper mounting and adequate ventilation.
  • Comply with all applicable electrical safety standards.
Frequently Asked Questions

1. What Incoterm is the quote based on?

All quotes are based on EXW.

2. What payment terms are accepted?

We accept 100% T/T before shipping.

3. What is the product warranty period?

Warranty for 1 year.

Related Products